*** PATCHES ******************************************************************** *** WARNING *** The following bucket consists of OPTIONAL patches that provide certain features or changes to features that customers have requested. If you wish to apply any of these, please read the documentation for each job before applying.. Panel/IMOD optional patches ---------- -------- ------- // JOB BF53160 /* CATALOG BF053160.fix TO the VIO PDS /* /* This optional patch changes &fp1jid=0 to &fp1jid=1 /* which displays JID=origin job number partially overlaying the /* User Information area on the POWER queue list display. /* /* This job only catalogs the fix to the VIO PDS. To activate /* this and other fixes you must run the BIM$UTFX imod using /* BIM$RXBA and then execute the generated BASOTEMP.PROC member /* that is created: /* /* // EXEC BIM$RXBA,PARM='BIM$UTFX S=lib.sublib P=BASO R=V5.3A' /* /* /* /* where lib.sublib is the location of your BIM-FAQS/ASO library. /* This process can be run multiple times without resulting in /* any problems or duplication. Each run will rebuild the PROC /* with all .fix members found for the requested product and release /* so that when you execute it all fixes are applied or reapplied. /* The original PROC's for this release are never modified. /* /* Be sure the CAT= below has 'fix' in lowercase... /* // OPTION LOG,LOGSRC // EXEC BIM$PUTL,SIZE=BIM$PUTL,PARM='INSTALL' PDS=VIO,CAT=BF053160.fix MEM=FAQMENP1.SDF PDS=VIO REL=V5.3A TYP=OPT E2C3C1D540C1D9C77E508697F19189847EF0FF D9C5D740F1FF 40404040508697F19189847EF140404040404040404040404040404040404040404061 5C40A285A340A39640F1408986409697A389969581937A40C2C6F1F8F6F9F84040405C 61FF 615BFF ./ END /* /& // JOB BF53161 /* CATALOG BF053161.fix TO the VIO PDS /* /* This optional patch sets change mode as the initial screen default /* instead of command mode. /* /* This job only catalogs the fix to the VIO PDS. To activate /* this and other fixes you must run the BIM$UTFX imod using /* BIM$RXBA and then execute the generated BASOTEMP.PROC member /* that is created: /* /* // EXEC BIM$RXBA,PARM='BIM$UTFX S=lib.sublib P=BASO R=V5.3A' /* /* /* /* where lib.sublib is the location of your BIM-FAQS/ASO library. /* This process can be run multiple times without resulting in /* any problems or duplication. Each run will rebuild the PROC /* with all .fix members found for the requested product and release /* so that when you execute it all fixes are applied or reapplied. /* The original PROC's for this release are never modified. /* /* Be sure the CAT= below has 'fix' in lowercase... /* // OPTION LOG,LOGSRC // EXEC BIM$PUTL,SIZE=BIM$PUTL,PARM='INSTALL' PDS=VIO,CAT=BF053161.fix MEM=FAQMENP1.SDF PDS=VIO REL=V5.3A TYP=OPT E2C3C1D540C1D9C77E508697F1A396877EF1FF D9C5D740F1FF 40404040508697F1A396877EF040404040404040404040615C40F17EC3D4C46B40F07E C3C8C74081A24084858681A493A340405C61FF 615BFF ./ END /* /& // JOB BF53162 /* CATALOG BF053162.fix TO the VIO PDS /* /* This optional patch allows users to delete POWER queue entries /* without requiring the PF10 key to be used. /* /* This job only catalogs the fix to the VIO PDS. To activate /* this and other fixes you must run the BIM$UTFX imod using /* BIM$RXBA and then execute the generated BASOTEMP.PROC member /* that is created: /* /* // EXEC BIM$RXBA,PARM='BIM$UTFX S=lib.sublib P=BASO R=V5.3A' /* /* /* /* where lib.sublib is the location of your BIM-FAQS/ASO library. /* This process can be run multiple times without resulting in /* any problems or duplication. Each run will rebuild the PROC /* with all .fix members found for the requested product and release /* so that when you execute it all fixes are applied or reapplied. /* The original PROC's for this release are never modified. /* /* Be sure the CAT= below has 'fix' in lowercase... /* // OPTION LOG,LOGSRC // EXEC BIM$PUTL,SIZE=BIM$PUTL,PARM='INSTALL' PDS=VIO,CAT=BF053162.fix MEM=FAQMENP1.SDF PDS=VIO REL=V5.3A TYP=OPT E2C3C1D540C1D9C77E898640837E7E7DD37D40504050C1C9C47E7E7DC17D40A3888595 408496FF D9C5D740F1FF 4040404040404040898640837E7E7DD37D40A3888595408496FF 615BFF ./ END /* /& // JOB BF53163 /* CATALOG BF053163.fix TO the VIO PDS /* /* This optional patch displays the full 16 characters of user /* information by removing the slashes from the date in each display /* line. /* /* This job only catalogs the fix to the VIO PDS. To activate /* this and other fixes you must run the BIM$UTFX imod using /* BIM$RXBA and then execute the generated BASOTEMP.PROC member /* that is created: /* /* // EXEC BIM$RXBA,PARM='BIM$UTFX S=lib.sublib P=BASO R=V5.3A' /* /* /* /* where lib.sublib is the location of your BIM-FAQS/ASO library. /* This process can be run multiple times without resulting in /* any problems or duplication. Each run will rebuild the PROC /* with all .fix members found for the requested product and release /* so that when you execute it all fixes are applied or reapplied. /* The original PROC's for this release are never modified. /* /* Be sure the CAT= below has 'fix' in lowercase... /* // OPTION LOG,LOGSRC // EXEC BIM$PUTL,SIZE=BIM$PUTL,PARM='INSTALL' PDS=VIO,CAT=BF053163.fix MEM=FAQMENP1.SDF PDS=VIO REL=V5.3A TYP=OPT E2C3C1D540C1D9C77E508697F1A489957EF0FF D9C5D740F1FF 40404040508697F1A489957EF140404040404040404040404040404040404040404061 5C40A285A340A39640F1408696994086A4939340A4A28599408995869640404040405C 61FF 615BFF ./ END /* /& // JOB BF53164 /* CATALOG BF053164.fix TO the VIO PDS /* /* This optional patch prevents SYSOUT archival member display /* users from deleting entries in the SYS$ARC PDS. /* /* This job only catalogs the fix to the VIO PDS. To activate /* this and other fixes you must run the BIM$UTFX imod using /* BIM$RXBA and then execute the generated BASOTEMP.PROC member /* that is created: /* /* // EXEC BIM$RXBA,PARM='BIM$UTFX S=lib.sublib P=BASO R=V5.3A' /* /* /* /* where lib.sublib is the location of your BIM-FAQS/ASO library. /* This process can be run multiple times without resulting in /* any problems or duplication. Each run will rebuild the PROC /* with all .fix members found for the requested product and release /* so that when you execute it all fixes are applied or reapplied. /* The original PROC's for this release are never modified. /* /* Be sure the CAT= below has 'fix' in lowercase... /* // OPTION LOG,LOGSRC /* /* // EXEC BIM$PUTL,SIZE=BIM$PUTL,PARM='INSTALL' PDS=VIO,CAT=BF053164.fix MEM=FAOMENUS.SDF PDS=VIO REL=V5.3A TYP=OPT E2C3C1D540C1D9C77E5DD3D360F140E0D37EC4859385A38540C27EC29996A6A28540D7 7ED7998995A34040404AFF D9C5D740F1FF 5DD3D360F140E0C27EC29996A6A28540D77ED7998995A34040404AFF 615BFF E2C3C1D540C1D9C77E898640835F7E7DD37D405040835F7E7DC27D405040835F7E7DD7 7D40A3888595FF D9C5D740F1FF 404040404040898640835F7E7DC27D405040835F7E7DD77D40A3888595FF 615BFF ./ END /* /& // JOB BF53165 /* CATALOG BF053165.fix TO the VIO PDS /* /* This optional patch changes the Display(D), Delete(L), AND Print(P) /* BIM-FAQS/ASO POWER commands agree with the BIMEDIT commands to avoid /* mistakes. These would be List(L), Purge(P), and then print is /* changed to O because P is in use by Purge. /* /* This job only catalogs the fix to the VIO PDS. To activate /* this and other fixes you must run the BIM$UTFX imod using /* BIM$RXBA and then execute the generated BASOTEMP.PROC member /* that is created: /* /* // EXEC BIM$RXBA,PARM='BIM$UTFX S=lib.sublib P=BASO R=V5.3A' /* /* /* /* where lib.sublib is the location of your BIM-FAQS/ASO library. /* This process can be run multiple times without resulting in /* any problems or duplication. Each run will rebuild the PROC /* with all .fix members found for the requested product and release /* so that when you execute it all fixes are applied or reapplied. /* The original PROC's for this release are never modified. /* /* Be sure the CAT= below has 'fix' in lowercase... /* // OPTION LOG,LOGSRC /* /* // EXEC BIM$PUTL,SIZE=BIM$PUTL,PARM='INSTALL' PDS=VIO,CAT=BF053165.fix MEM=FAQMENP1.SDF PDS=VIO REL=V5.3A TYP=OPT E2C3C1D540C1D9C77E508697F18294857EF0FF D9C5D740F1FF 40404040508697F18294857EF140404040404040404040404040404040404040404061 5C40A285A340A39640F1408986409697A389969581937A40C2C6F1F9F4F3F74040405C 61FF 615BFF ./ END /* /& // JOB BF53166 /* CATALOG BF053166.fix TO the VIO PDS /* /* This optional patch changes the D A initial display to be All instead /* of Que. The toggle will be the same except for its initial starting /* point. /* /* This job only catalogs the fix to the VIO PDS. To activate /* this and other fixes you must run the BIM$UTFX imod using /* BIM$RXBA and then execute the generated BASOTEMP.PROC member /* that is created: /* /* // EXEC BIM$RXBA,PARM='BIM$UTFX S=lib.sublib P=BASO R=V5.3A' /* /* /* /* where lib.sublib is the location of your BIM-FAQS/ASO library. /* This process can be run multiple times without resulting in /* any problems or duplication. Each run will rebuild the PROC /* with all .fix members found for the requested product and release /* so that when you execute it all fixes are applied or reapplied. /* The original PROC's for this release are never modified. /* /* Be sure the CAT= below has 'fix' in lowercase... /* // OPTION LOG,LOGSRC /* /* // EXEC BIM$PUTL,SIZE=BIM$PUTL,PARM='INSTALL' PDS=VIO,CAT=BF053166.fix MEM=FAQMENP2.SDF PDS=VIO REL=V5.3A TYP=OPT 40E2C3C1D540C1D9C77E508697F2818193937EF0FF D9C5D740F1FF 40508697F2818193937EF2404040404040404040404040404040404040404040404061 5C40A285A340A39640F2408986409697A389969581937A40C2C6F1F9F4F8F04040405C 61FF 615BFF ./ END /* /& // JOB BF53167 /* CATALOG BF053167.fix TO the VIO PDS /* /* This optional patch changes the BIM-FAQS/ASO POWER queue display /* screen to display TO= information initially instead of DATE and /* TIME. The toggle works the same. Only the initial setting has /* been changed. /* /* This job only catalogs the fix to the VIO PDS. To activate /* this and other fixes you must run the BIM$UTFX imod using /* BIM$RXBA and then execute the generated BASOTEMP.PROC member /* that is created: /* /* // EXEC BIM$RXBA,PARM='BIM$UTFX S=lib.sublib P=BASO R=V5.3A' /* /* /* /* where lib.sublib is the location of your BIM-FAQS/ASO library. /* This process can be run multiple times without resulting in /* any problems or duplication. Each run will rebuild the PROC /* with all .fix members found for the requested product and release /* so that when you execute it all fixes are applied or reapplied. /* The original PROC's for this release are never modified. /* /* Be sure the CAT= below has 'fix' in lowercase... /* // OPTION LOG,LOGSRC /* /* // EXEC BIM$PUTL,SIZE=BIM$PUTL,PARM='INSTALL' PDS=VIO,CAT=BF053167.fix MEM=FAQMENP1.SDF PDS=VIO REL=V5.3A TYP=OPT 40E2C3C1D540C1D9C77E508697F184A3877EF0FF D9C5D740F1FF 40404040508697F184A3877EF240404040404040404040404040404040404040404061 5C40A285A340A39640F2408986409697A389969581937A40C2C6F1F9F4F8F44040405C 61FF 615BFF ./ END /* /& // JOB BF53168 /* CATALOG BF053168.fix TO the VIO PDS /* /* This optional patch changes the BIM-FAQS/ASO POWER queue display /* screen to maximize the number of lines of data displayed. Each /* MOD terminal now has 5 more lines of POWER Queue entries. /* /* This job only catalogs the fix to the VIO PDS. To activate /* this and other fixes you must run the BIM$UTFX imod using /* BIM$RXBA and then execute the generated BASOTEMP.PROC member /* that is created: /* /* // EXEC BIM$RXBA,PARM='BIM$UTFX S=lib.sublib P=BASO R=V5.3A' /* /* /* /* where lib.sublib is the location of your BIM-FAQS/ASO library. /* This process can be run multiple times without resulting in /* any problems or duplication. Each run will rebuild the PROC /* with all .fix members found for the requested product and release /* so that when you execute it all fixes are applied or reapplied. /* The original PROC's for this release are never modified. /* /* Be sure the CAT= below has 'fix' in lowercase... /* // OPTION LOG,LOGSRC /* /* // EXEC BIM$PUTL,SIZE=BIM$PUTL,PARM='INSTALL' PDS=VIO,CAT=BF053168.fix MEM=FAQMENP1.SDF PDS=VIO REL=V5.3A TYP=OPT E2C3C1D540C1D9C77E508697F19481A77EF0FF D9C5D740F1FF 40508697F19481A77EF140404040404040404040404040404040404040404040404061 5C40A285A340A39640F1408986409697A389969581937A40C2C6F1F9F4F8F64040405C 61FF 615BFF ./ END /* /& // JOB BF53169 /* CATALOG BF053169.fix TO the VIO PDS /* /* This optional patch suppresses the print to BIM-GSS CPR facility /* within the POWER Queue list display and the queue alter display /* panels. /* /* This job only catalogs the fix to the VIO PDS. To activate /* this and other fixes you must run the BIM$UTFX imod using /* BIM$RXBA and then execute the generated BASOTEMP.PROC member /* that is created: /* /* // EXEC BIM$RXBA,PARM='BIM$UTFX S=lib.sublib P=BASO R=V5.3A' /* /* /* /* where lib.sublib is the location of your BIM-FAQS/ASO library. /* This process can be run multiple times without resulting in /* any problems or duplication. Each run will rebuild the PROC /* with all .fix members found for the requested product and release /* so that when you execute it all fixes are applied or reapplied. /* The original PROC's for this release are never modified. /* /* Be sure the CAT= below has 'fix' in lowercase... /* // OPTION LOG,LOGSRC /* /* // EXEC BIM$PUTL,SIZE=BIM$PUTL,PARM='INSTALL' PDS=VIO,CAT=BF053169.fix MEM=FAQMENP1.SDF PDS=VIO REL=V5.3A TYP=OPT E2C3C1D540C1D9C77E508697F197A2A4977EF0FF D9C5D740F1FF 40404040508697F197A2A4977EF1404040404040404040404040404040404040404061 5C40A285A340A39640F1408986409697A389969581937A40C2C6F5F2F4F6F94040405C 61FF 615BFF ./ END /* /& // JOB BF53170 /* /* In order to access CA-EPIC from the BIM-FAQS/ASO on-line /* interface, you must define the following on-line command. /* Enter "AO I.O" from the BIM-FAQS/ASO command line to get /* to the proper panel. Enter an "A" next to an entry and /* set as follows: /* /* New Command: EPIC /* Replacement Command: .P=FAQMENU0.V.EPIC @ @ @ @ @ @ /* Set YES for "Allow arguments to be passed ... command" /* Set No for "Also pass COMMAND as the first variable" /* /* Use PF5 to save the new command, PF3 to return to the previous /* panel, and then PF6 to load the changed on-line command file. /* /* See the BIM-FAQS/ASO On-line User's guide for more information. /* /* /& // JOB BF53171 /* CATALOG BF053171.fix TO the VIO PDS /* /* This optional patch suppresses the new sorting feature within /* the POWER Queue list display. /* /* This job only catalogs the fix to the VIO PDS. To activate /* this and other fixes you must run the BIM$UTFX imod using /* BIM$RXBA and then execute the generated BASOTEMP.PROC member /* that is created: /* /* // EXEC BIM$RXBA,PARM='BIM$UTFX S=lib.sublib P=BASO R=V5.3A' /* /* /* /* where lib.sublib is the location of your BIM-FAQS/ASO library. /* This process can be run multiple times without resulting in /* any problems or duplication. Each run will rebuild the PROC /* with all .fix members found for the requested product and release /* so that when you execute it all fixes are applied or reapplied. /* The original PROC's for this release are never modified. /* /* Be sure the CAT= below has 'fix' in lowercase... /* // OPTION LOG,LOGSRC /* /* // EXEC BIM$PUTL,SIZE=BIM$PUTL,PARM='INSTALL' PDS=VIO,CAT=BF053171.fix MEM=FAQMENP1.SDF PDS=VIO REL=V5.3A TYP=OPT E2C3C1D540C1D9C77E508697F1A299A37EF1FF D9C5D740F1FF 40404040508697F1A299A37EF0404040404040404040FF 615BFF ./ END /* /& // JOB BF53172 /* CATALOG BF053172.fix TO the VIO PDS /* /* This optional patch allows you to determine the maximum number /* of POWER queue entries that may be sorted using the new sorting /* feature within the POWER Queue member list display. In the line /* below that starts with "405086", replace the "????????" with the /* hex display value of the limit you wish to use. For example, if /* you want a limit of decimal 2000 members, you would change to /* "F2F0F0F0". /* /* This job only catalogs the fix to the VIO PDS. To activate /* this and other fixes you must run the BIM$UTFX imod using /* BIM$RXBA and then execute the generated BASOTEMP.PROC member /* that is created: /* /* // EXEC BIM$RXBA,PARM='BIM$UTFX S=lib.sublib P=BASO R=V5.3A' /* /* /* /* where lib.sublib is the location of your BIM-FAQS/ASO library. /* This process can be run multiple times without resulting in /* any problems or duplication. Each run will rebuild the PROC /* with all .fix members found for the requested product and release /* so that when you execute it all fixes are applied or reapplied. /* The original PROC's for this release are never modified. /* /* Be sure the CAT= below has 'fix' in lowercase... /* // OPTION LOG,LOGSRC /* /* // EXEC BIM$PUTL,SIZE=BIM$PUTL,PARM='INSTALL' PDS=VIO,CAT=BF053172.fix MEM=FAQMENP1.SDF PDS=VIO REL=V5.3A TYP=OPT E2C3C1D540C1D9C77E508697F1A299A394A77EFF 99859740F1FF 40508697F1A299A394A77E????????4040404040404040404040404040404040404061 5C40A285A340A39640A58193A485408986409697A3899695819340404040404040405C 61FF 615BFF ./ END /* /& **************************************************************************** PHASE optional patches ----- -------- ------- // JOB BF53175 /* /* THIS OPTIONAL PATCH ALLOWS THE WAIT TIME BETWEEN COMMAND /* REQUESTS FROM FAQSOPER TO BE CHANGED BY DEFAULT. IN THE /* ALTER 000568 LINE, CHANGE THE XX TO THE VALUE YOU WANT AS /* THE DEFAULT IN SECONDS IN HEXADECIMAL FORMAT. /* /* // EXEC MSHP,SIZE=900K CORRECT 2885-BF2-00-53A : BF53175 AFFECTS PHASE=FAQSOPER ALTER 000568 00000005 : 000000XX RESOLVES '(O) CHANGE COMMAND WAIT DEFLT' /* /& // JOB BF53176 /* /* This patch provides DBCS for POWER member display. /* // EXEC MSHP,SIZE=900K CORRECT 2885-BF2-00-53A : BF53176 AFFECT PHASE=FAQSPWR6 ALTER 005686 47F0 : 4700 AFFECT PHASE=FAQSPW64 ALTER 00581E 47F0 : 4700 AFFECT PHASE=FAQSPW67 ALTER 00581E 47F0 : 4700 RESOLVES '(O) POWER DISPLAY DBCS SUPPORT' /* /& // JOB BF53177 /* /* THIS OPTIONAL PATCH ALLOWS YOU TO USE THE "PROFILE" SECURITY /* ENTRY TO ALLOW USERS TO ENTER BIM-FAQS/ASO ON-LINE WHEN THE /* SCTY ENTRY FOR A USER INDICATES THEY ARE NOT PERMITTED. THIS /* ALLOWS YOU TO RESTRICT A GIVEN USER BASED ON THE VSE MACHINE /* HE/SHE IS ATTEMPTING TO ACCESS, WHILE ALLOWING THE NORMAL AUTO /* SIGN ON PROCESS. FOR THE USERS AFFECTED, CHANGE THEIR SCTY: /* /* VM MACHINE ALL INCLUDE EXCLUDE USER-ID USER-ID ... /* RESTRICTIONS ( X ) ( ) ( ) ________ ________... /* /* TO INCLUDE OR EXCLUDE THE VSE SYSTEMS YOU WANT A GIVEN USER TO /* USE THE DEFAULT PROFILE. THE USER-ID FOR EACH BIM-FAQS/ASO /* ON-LINE PARTITION IS DETERMINED BY THE "NM=" VALUE IN GFX402I: /* /* GFX402I FAQSMAIN ACTIVATED, NM=VB31 ID=FAQSTXPC /* /* NOTE: YOU WILL ALSO NEED TO APPLY OPTIONAL PATCH BF53187 IF YOU /* NEED TO INCLUDE INTERFACES OTHER THAN IUCV/VMCF. /* // EXEC MSHP,SIZE=900K CORRECT 2885-BF2-00-53A : BF53177 REQUIRES PRE=BF53120 AFFECTS PHASE=FAQSMAIN ALTER 4EC6 47F027EE : 47F02726 RESOLVES '(O) RESTRICT FAQS USERS' /* /& // JOB BF53178 /* /* THIS OPTIONAL PATCH ALLOWS ONLY THE STACKED REPLIES TO BE DISPLAYED /* INSTEAD OF DISPLAYING ALL OF THE MESSAGE, ETC. ENTRIES. THIS /* FEATURE IS ACTIVATED BY USING THE ASO MSG REPLY FUNCTION INSTEAD /* OF THE ASO MSG. WITHOUT THIS PATCH, ASO MSG PROVIDES FOR NO /* ADDITIONAL PARAMETERS. /* /* // EXEC MSHP,SIZE=900K CORRECT 2885-BF2-00-53A : BF53178 AFFECTS PHASE=$FAQS ALTER 000C7C 0000000000000000 : 4780E9BE95D95004 ALTER 000C84 000000000000 : 4780E9DA07F2 ALTER 0010C4 4780E9BE : 45201C7C RESOLVES '(O) SUPPORT ASO MSG REPLY' /* /& // JOB BF53179 /* /* THIS OPTIONAL PATCH ALLOWS DISPLAY OF THE POWER JOB NAME FOR /* PARTITIONS, WHEN AVAILABLE, INSTEAD OF THE VSE JOB NAME. /* /* THIS PATCH IS FOR THE ON-LINE COMMANDS D S,S; D S,J; D S,W; /* AND ASO J FOR BIM-FAQS/ASO. /* /* // EXEC MSHP,SIZE=900K CORRECT 2885-BF2-00-53A : BF53179 REQUIRES PRE=BF53120 AFFECTS PHASE=FAQSMAIN ALTER 00A968 47F0 : 4700 RESOLVES '(O) USE POWER JOB NAME FOR D S' /* /& // JOB BF53180 /* /* CHANGE XX IN ALTER TO CREATE DESIRED DISPLAY. BITS CAN /* AND'D TO CREATE DIFFERENT COMBINATIONS AS FOLLOWS: /* /* WHERE XX= 80 - SKIP SUBTASKS /* 40 - INCLUDE WAIT BOUND TASKS /* A0 - SKIP ALL PHASE LINES /* E0 - SIMULATE MLOG DISPLAY /* // EXEC MSHP,SIZE=900K CORRECT 2885-BF2-00-53A : BF53180 REQUIRES PRE=BF53120 AFFECT PHASE=FAQSMAIN ALTER 00996C 00:XX RESOLVES '(O) CHANGE D S,W DISPLAY' /* /& // JOB BF53181 // EXEC MSHP,SIZE=900K CORRECT 2885-BF2-00-53A:BF53181 REQUIRES PRE=BF53120 AFFECTS PHASE=FAQSMAIN ALTER 2440 40404040404040 : 8A8B8C8D8E8F90 ALTER 2450 4040404040404040 : 9A9B9C9D9E9FA9A1 ALTER 2460 404040AD4040 : AAABACADAEAF ALTER 2470 404040BD4040 : BABBBCBDBEBF AFFECTS PHASE=FAQXCONS ALTER 7282 40404040404040 : 8A8B8C8D8E8F90 ALTER 7292 4040404040404040 : 9A9B9C9D9E9FA9A1 ALTER 72A2 404040AD4040 : AAABACADAEAF ALTER 72B2 404040BD4040 : BABBBCBDBEBF RESOLVES '(O) SUPPORT ALL KATAKANA CHARS' /* /& // JOB BF53182 /* /* CHANGE Fx TO ONE OF THE FOLLOWING VALUES: /* /* F1=BLUE, F2=RED, F3=PINK, F4=GREEN, F5=TURQUOISE /* F6=YELLOW, OR F7=WHITE /* /* This change applies to hardcopy records beyond the /* area contained within the cache only. /* /* // EXEC MSHP,SIZE=900K CORRECT 2885-BF2-00-53A : BF53182 REQUIRES PRE=BF53120 AFFECT PHASE=FAQXCONS ALTER 00236C 94FF : 92Fx RESOLVES '(O) CHANGE REDISPLAY COLOR' /* /& // JOB BF53183 /* /* This patch allows the use of POWER job name for GSFAQS /* message handling for job name selection. /* // EXEC MSHP,SIZE=900K CORRECT 2885-BF2-00-53A : BF53183 AFFECT PHASE=GSFAQS ALTER 009BE6 4700 : 47F0 RESOLVES '(O) USE POWER JOBNAME FOR MID' /* /& // JOB BF53184 /* /* CHANGE THE XXXX IN THE PATCH TO THE NUMBER OF BYTES TO ALLOCATE TO /* THE LINE ADDRESS TABLE. 1000 WOULD GIVE YOU 4K WHICH SHOULD BE MORE /* THAN ENOUGH. /* /* NOTE: THE INITIAL SETTING IS NOW 4K, SO IT SHOULD BE RARE THAT YOU /* NEED TO APPLY THIS PATCH. // EXEC MSHP,SIZE=900K CORRECT 2885-BF2-00-53A : BF53184 AFFECT PHASE=FAQSPWR6 ALTER 000082 1000 : xxxx AFFECT PHASE=FAQSPW64 ALTER 000082 1000 : xxxx AFFECT PHASE=FAQSPW67 ALTER 000082 1000 : xxxx RESOLVES '(O) CORRECT GFP002E RC=05' /* /& // JOB BF53185 /* This optional patch allows support of up to 100 steps in /* the eoj console summary report instead of just 8. // EXEC MSHP,SIZE=900K CORRECT 2885-BF2-00-53A : BF53185 AFFECT PHASE=GSJOBCTL ALTER 11D8 41100008 : 41100064 ALTER 1350 41000130 : 41000E20 ALTER 1374 41100008 : 41100064 RESOLVES '(O) EOJ SUM RPT MAX STEPS=100' /* /& // JOB BF53186 /* This optional patch disassociates transfer from member edit /* security for POWER members for BIM-FAQS/ASO security. // EXEC MSHP,SIZE=900K CORRECT 2885-BF2-00-53A : BF53186 AFFECT PHASE=FAQSPWR6 ALTER 47C2 47E0 : 4700 AFFECT PHASE=FAQSPW64 ALTER 495A 47E0 : 4700 AFFECT PHASE=FAQSPW67 ALTER 495A 47E0 : 4700 RESOLVES '(O) REMOVE TRANSFER EDIT SCTY' /* /& // JOB BF53187 /* This optional patch allows control of BIM-FAQS/ASO user /* access based on the machine name for all interface users .* instead of just for CMS interface (IUCV/VMCF) users. // EXEC MSHP,SIZE=900K CORRECT 2885-BF2-00-53A : BF53187 REQUIRES PRE=BF53120 AFFECT PHASE=FAQSMAIN ALTER 4EA0 0785 : 0705 RESOLVES '(O) CHECK CMS ID FOR VSE' /* /& // JOB BF53188 // EXEC MSHP,SIZE=900K CORRECT 2885-BF2-00-53A : BF53188 AFFECT PHASE=GSJOBCTL ALTER 10A4 96809DAC : 47F090FC RESOLVES '(O) DISABLE CQON/CQOFF' /* /& // JOB BF53189 /* /* /* This patch is provided, but no longer needed since the MAX command /* is now available. See POWER display HELP for more details. /* /* /* This optional patch allows you to change the maximum number of /* lines to scan before allowing another user to get access (TSHARE). /* If you want faster access to scan data, increase this value. If /* you decrease this value, more users get access but each one has /* less of a timeslice per access. If you set this value to 0000, /* TSHARE during scans is disabled. Do not exceed 7FFF (32767) since /* the access is via halfword commands. /* // EXEC MSHP,SIZE=900K CORRECT 2885-BF2-00-53A : BF53189 AFFECT PHASE=FAQSPWR6 ALTER 0084 1388 : xxxx AFFECT PHASE=FAQSPW64 ALTER 0084 1388 : xxxx AFFECT PHASE=FAQSPW67 ALTER 0084 1388 : xxxx RESOLVES '(O) CHANGE SCAN LINE MAX' /* /& // JOB BF53190 /* /* THIS PATCH SUPPRESSES THE ACTION/OPTION PW LINES /* FROM THE BIM-FAQS/ASO POWER MEMBER DISPLAY. /* /* // EXEC MSHP,SIZE=900K CORRECT 2885-BF2-00-53A : BF53190 AFFECT PHASE=FAQSPWR6 ALTER 0060AC 4700 : 4780 AFFECT PHASE=FAQSPW64 ALTER 006244 4700 : 4780 AFFECT PHASE=FAQSPW67 ALTER 006244 4700 : 4780 RESOLVES '(O) SUPPRESS ACTION/OPTION PW=' /* /& // JOB BF53191 /* /* THIS OPTIONAL PATCH CAUSES THE FBUF= VALUE SELECTED /* DURING GSFTL STARTUP TO BE DOUBLE WHAT IS SPECIFIED. /* /* // EXEC MSHP,SIZE=900K CORRECT 2885-BF2-00-53A : BF53191 REQUIRES PRE=BF53110 AFFECT PHASE=GSFTL ALTER 0007BE 89F0000A : 89F0000B RESOLVES '(O) DOUBLE FBUF= SIZE IN GSFTL' /* /& // JOB BF53192 /* /* THIS OPTIONAL PATCH ALLOWS YOU TO USE THE POWER JOBNAME FOR /* INDEX/DISPLAY INSTEAD OF THE DOS JOBNAME. /* /* // EXEC MSHP,SIZE=900K CORRECT 2885-BF2-00-53A : BF53192 REQUIRES PRE=BF53110 AFFECT PHASE=GSFAQSHC ALTER 00134E 4700 : 4780 ALTER 001358 4700 : 4770 ALTER 00135C 4700 : 47F0 RESOLVES '(O) INDEX BY POWER JOBNAME' /* /& // JOB BF53193 /* /* THIS OPTIONAL PATCH CAUSES SYSOUT ARCHIVAL MEMBERS TO USE /* THE POWER JOB NAME INSTEAD OF THE VSE JOB NAME. /* /* // EXEC MSHP,SIZE=900K CORRECT 2885-BF2-00-53A : BF53193 AFFECT PHASE=GSJOBCTL ALTER 0039AE 47F0 : 4700 RESOLVES '(O) POWER JOB NAME FOR SYSOUT' /* /& // JOB BF53194 /* /* THIS OPTIONAL PATCH ALLOWS THE ID CARD IN POWER MEMBERS TO /* BE PASSED AS IS INSTEAD OF BEING SUPPRESSED WHEN EDITTING. /* /* // EXEC MSHP,SIZE=900K CORRECT 2885-BF2-00-53A : BF53194 AFFECT PHASE=FAQSPWR6 ALTER 00611C 4710A1E8 : 07150700 AFFECT PHASE=FAQSPW64 ALTER 0062B4 4710A1E8 : 07150700 AFFECT PHASE=FAQSPW67 ALTER 0062B4 4710A1E8 : 07150700 RESOLVES '(O) ALLOW ID CARD EDIT' /* /& // JOB BF53195 /* /* THIS OPTIONAL FIX CHANGES THE NUMBER OF DATA LINES RETURNED FROM /* FAQSVSPO (VTAM FUNCTION) FROM 64 TO A USER SPECIFIED NUMBER. THE /* FORMULA FOR 'XXX' BELOW IS THE HEXADECIMAL VALUE OF THE NUMBER OF /* LINES TIMES 4 WITH A MAXIMUM OF 200 LINES. SO IF YOU WANT THE 200 /* MAXIMUM YOU WOULD TAKE 200 * 4 = 800, so XXX would be 320. /* // EXEC MSHP,SIZE=900K CORRECT 2885-BF2-00-53A : BF53195 REQUIRES PRE=BF53120 AFFECTS PHASE=FAQSVSPO ALTER 000040 00000100 : 00000XXX AFFECTS PHASE=FAOXSFN ALTER 004720 41001100 : 41001XXX RESOLVES '(O) CHANGE MAX VTAM() LINES' /* /& // JOB BF53196 /* /* THIS OPTIONAL PATCH PREVENTS USERS FROM LOOKING BACK BEYOND /* THE DEFINED BIM-FAQS/ASO HARDCOPY FILE CACHE. THREE EXCEPTIONS /* TO THIS ARE THE DATE/TIME PARAMETERS AND THE S=IPL SPECIAL /* PARAMETER WHICH WILL STILL ACCESS THE HARDCOPY FILE. /* /* // EXEC MSHP,SIZE=900K CORRECT 2885-BF2-00-53A : BF53196 REQUIRES PRE=BF53120 AFFECTS PHASE=FAQXCONS ALTER 00579A 4700 : 47F0 RESOLVES '(O) RESTRICT HC FILE ACCESS' /* /& // JOB BF53197 /* /* THIS OPTIONAL PATCH ENABLES DISPLAY OF MESSAGE GFF398I WHICH /* PROVIDES A MESSAGE FOR EACH SYSOUT ARCHIVAL MEMBER CREATED THAT /* CONTAINS THE CREATED MEMBER NAME IN DISPLAY HEX FORMAT AND THE /* NAME OF THE JOB IT WAS CREATED FOR. /* /* // EXEC MSHP,SIZE=900K CORRECT 2885-BF2-00-53A : BF53197 AFFECTS PHASE=GSJOBCTL ALTER 00000F8C 07F5 : 0705 RESOLVES '(O) SUPPORT FOR GFF398I' /* /& // JOB BF53198 /* /* THIS OPTIONAL PATCH ESTABLISHES A NON-ZERO RETURN CODE FOR /* JOBS THAT ARE CANCELLED OR OTHERWISE ABEND BUT THE MAXRC /* REMAINED AT ZERO. This patch will set the MAXRC value for /* SYSOUT archival purposes to be 16 (x'10'). If you want to /* set a different return code, change the F0F0F1F6 to another /* value. For example to set the return code to 1024, you would /* change F0F0F1F6 to F1F0F2F4. /* /* // EXEC MSHP,SIZE=900K CORRECT 2885-BF2-00-53A : BF53198 AFFECTS PHASE=GSJOBCTL ALTER 00003890 F0F0F0F0 : F0F0F1F6 ALTER 00003AA6 47F0 : 4700 RESOLVES '(O) SET RC ON CANCEL IF MRC=0' /* /& // JOB BF53199 /* /* OPTIONAL PATCH TO STOP ID SUPPRESSION FOR POWER RDR QUEUE /* MEMBERS. /* /* // EXEC MSHP,SIZE=900K CORRECT 2885-BF2-00-53A : BF53199 AFFECTS PHASE=FAQSPW67 ALTER 00621C 0775 : 07F5 AFFECTS PHASE=FAQSPW64 ALTER 00621C 0775 : 07F5 AFFECTS PHASE=FAQSPWR6 ALTER 006084 0775 : 07F5 RESOLVES '(O) STOP ID SUPPRESS' /* /& ******************************************************************************** Obsolete optional patches -------- -------- ------- // JOB BF19082 /* /* THIS OPTIONAL PATCH ALLOWS THE COLOR OF D S,X STATUS SCREENS TO /* BE CHANGED BASED ON CPUID OR MACHINE NAME. /* /* This patch has been replaced by the STATS (S=x/y) parameter during /* FAQSMAIN start up. The new parameter is (S)TATS=clr/atr, where /* clr is the one of the colors (RED,GRE,BLU,TUR,WHI,YEL,or PIN) and /* atr is UND, REV, BLI, or NOR ... For example, to change the status /* area to green and reverse you would add the following parameter to /* FAQSMAIN start up: /* /* S=GRE/REV /* /& // JOB BF19083 /* CATALOG BF019083.fix TO the VIO PDS /* /* This optional patch allows you to change the port number used by /* the BIM-FAQS/ASO HTML interface to agree with the defined port /* number for your HTTP Daemon. This patch is only necessary if that /* port number is not the default value of 80. /* /* This patch is no longer necessary because you can now enter the /* port number in the HTML document instead of this IMOD. Please /* see the cover letter and/or the sample TXT documents named /* FAQScgic and FAQScgip for more information.. /* /&